The accumulation tanks ATTACK HRS are made from the quality steel and serve for accumulation of the heating water as well as for preparation of the D.H.W. by an internal enameled exchanger. The ATTACK HRS600K model is accessorized with an extra exchanger to be connected to the solar system. Tanks of this type have a built-in magnesium anode in the D.H.W. tank to increase resistance against corrosion.
ATTACK HRS: 10x socket G 1 1/2", 6x socket G 1/2", 2x socket G 1" – solar circuit, 2x socket G 1" – D.H.W.
ATTACK HRS: 10x socket G 1 1/2", 6x socket G 1/2", 2x socket G 1" – solar circuit, 2x socket G 1" – D.H.W.
| Position 1-6 | 1515 |
| Position 2-7 | 1123 |
| Position 3 | 794 |
| L-max. length of the el. heating body | 650 |
| Position 4-8 | 684 |
| Position 5-9 | 245 |
| Position RS | 245 |
| Position AS | 725 |
| Ø D1 – Diameter without insulation | 700 |
| Ø D2 – Diameter with insulation of 100 mm | 900 |
| Height | 1754 |
| Height with insulation of 100 mm | 1854 |
| R – Slope dimension without insulation | 1841 |
| Max. operating temperature | 95° °C |
| Max. operating pressure | 3 bar |
| Area of exchanger | 1,8 m² |
| Volume of exchanger | 11,9 l |
| Max. operating pressure | 10 bar |
| Volume | 160 l |
| Max. operating temperature | 95° °C |
| Max. operating pressure | 6 bar |
| Volume | 445 l |
| Weight | 157 kg |