Additional flue gas draught fan PV150
Additional flue gas draught fan PV150

Additional flue gas draught fan PV150

Additional flue gas draught fan ATTACK® PV150 compensates insufficient or uneven chimney draught during the combustion process. It also ensures more effective the flow of flue gases. It is also useful during the time of loading when the boiler door are open. The additional flue draught fan prevents the escape of smoke from the boiler into the boiler room.
The unit is designed to evenly exhaust the flue gases from the boiler. This can save fuel and ensure that combustion in the boiler is efficient.

CHIMNEY DRAUGHT

The chimney must have sufficient draught and reliably evacuate combustion gases into the air during all possibilities of operating operation. The correct dimension of the flue is necessary for correct boiler operation, boiler combustion, output and life time are dependent on flue diameter.

 

TECHNICAL DESCRIPTION

Additional flue gas draught fan compensates insufficient or uneven chimney draught during the combustion process. It also ensures more effective the flow of flue gases. It is also useful during the time of loading when the boiler door are open. The additional flue draught fan prevents the escape of smoke from the boiler into the boiler room.
The unit is designed to evenly exhaust the flue gases from the boiler. This can save fuel and en-sure that combustion in the boiler is efficient.
The body of additional draught is welded from sheet of 2 or 3 mm thickness. Direction of flue gases flow indicates the arrow on the side of the body. Input connection with 152 mm diameter inside is connection to boiler chimney draught outlet with diameter 150 mm. Output connection with 149 mm diameter inside is connection to flue connection. Exhaust fan is connected to the flange by 4 mm plate. Radial impeller is directly connected to electromotor shaft. Additional ex-haust fan is connected to the flange, also with radial impeller. This part is connected by nuts and bolts to the additional flue gas draught body.

This unit is suitable for following ATTACK® boilers:
ATTACK DP 25 – ATTACK DP 45
ATTACK DPX 15 – ATTACK DPX 45
ATTACK SLX 20 – ATTACK SLX 55
ATTACK WOOD&PELLET 25

Input connection 152 mm
Output connection 149 mm
Total weight 9,6 kg
Width 205 mm
Height 360 mm
Depth 400 mm
Connecting voltage 230 V/Hz / 50 V/Hz
Electrical input 38 W
Output 19 W
Current 0,17 A
Rotation 2760 rot./min.
Capacitor 1 μF/V / 400 μF/V
Engine weight 2,4 kg