ATTACK DP PROFI

The ATTACK PROFI of the „PID“ generation is a kind of the advanced regulator, which enables to modulate the heat output in the ATTACK® wood gasifying boilers by regulation of the fan rotations. The well-readable display shows the necessary information and makes the boiler control easier.
The ATTACK DP PROFI boiler brings the improvement of the PID regulation to control the fan rotations according to the temperature of water and flue gas and thereby to achieve the optimal efficiency. The regulator uses the advanced Fuzzy logic system for control to regulate the wood gasification system in the optimal way – to ensure the lowest heat loss possible.
The boiler equipped with the regulator ATTACK PROFI „PID” can control the heating system equipped with the following items: a pump for charging the accumulation tank, accumulation tank, circuit pump of heating circuits and room thermostat, by the lowest loss of heat energy possible. The regulator can be connected and set in the way enabling to control the pump of heating circuits and pump to charge the tank for domestic hot water.

THE MAIN ADVANTAGES OF REGULATION:

  • Innovated electronics with fluent PID regulation of the fan rotations according to the flue gas temperature
  • Fuzzy logic – optimal regulation of the operating cycle of wood burning
  • Increased boiler efficiency and stable burning
  • Several options of control, including the pump to charge the accumulation tank, pump to charge the D.H.W. tank and the circuit pump of the heating circuits
  • Option to control the circuit pump by thermostat
  • Well-readable display indicating the operation of particular elements
DP PROFI – Control Panel

DESCRIPTION:

  1. 0/1 – main switch of electronics
  2. OK – button to confirm the parameters in menu
  3. STOP – button to stop the boiler and to browse the menu
  4. START – button to start the boiler and to browse the menu
  5. Small propeller sign – icon indicating the fan operation
  6. Water tap sign – icon indicating operation of the pump to charge the D.H.W. tank or the accumulation tank
  7. Pump sign – icon indicating operation of the circuit pump of heating circuits
  8. Key sign – icon indicating enter into the menu of settings
  9. Warning triangle – icon indicating the dangerous state
  10. Info sign – icon indicating browsing the information menu
  11. Thermo-manometer