ATTACK DPX LAMBDA

The wood gasifying boiler ATTACK DPX Lambda disposes with the most advanced technology of the combustion process control to achieve the excellent values of emissions and efficiency. Controller can individually regulate amount of the primary and the secondary air, adequately to data about oxygene content from Lambda probe, boiler temperature and flue gas temperature. All the operation parameters are displayed on the well-readable multiline LCD display. The parameters can be change via buttons placed on the control panel of the boiler. Eventual error or warning messages are signalized by flickering LED diodes.

After the fuel burn-out is the boiler automatically stopped according to the flue gas temperature or the oxygene content in the flue gas. All modifications of the ATTACK DPX boilers can be equipped with an additional regulator which ensures control of the accumulation tank, solar panels or other sources of heat energy in different designs of the heating systems, according to the customer´s demands.

DPX Lambda Termostat
  1. Control light of the boiler operation – lights by the boiler start with the „+“ (5) button, expires after burning out of fuel or after manual boiler stop by the „–“ (6) button
  2. Control light of error messages – lights in case of the following faults: Wrong value of the flue gas temperature
  3. Control light of warnings – following fault importance: Reset – lights, Wrong boiler temperature – lights, Too high temperature – flickers, Boiler overheating – do not open (boiler temperature over 90°C) – flickers
  4. Multi-line LCD display – displays operation data and enables browsing the menu. If the boiler is out of operation for longer than 15 min. and does not display any error, the display illumination is turned off automatically.
  5. Button for boiler start and parameter change – turns on display illumination. After repeated pressing turns the boiler on or enables fuel feeding.
  6. Button for boiler stop and parameter change – serves for emergency boiler stop - only in case, that there is no water in the system or if the sensor for overheating does not work.
  7. Enter (button for confirmation and entering into the menu) – serves for entering the menu and confirmation of the required value.
  8. Reset – button of the boiler‘s safety protection against overheating. If the temperature of the boiler‘s water exceeds 95°C, the boiler stops. The boiler can be started by unmounting the cover and pressing the button, after temperature decrease to 85°C.
  9. Thermomanometer
Displayed count: 244896