ATTACK DPX Standard

The wood gasifying boiler ATTACK DPX Standard is controlled by the boiler and the flue gas thermostat.

DPX Standard Termostat
  1. Reset – boiler protection against overheating (after exceeding temperature of 95°C is the boiler disconnected from electricity mains)
  2. Fuse – protection against short circuit
  3. Main switch – boiler start and boiler stop for the case of need
  4. Flue gas thermostat – when the temperature of the flue gas decreases under adjusted value, the fan is switched off
  5. Boiler thermostat – serves to set the required temperature of the water in the boiler (in case of exceeding the adjusted temperature is the fan switched off and the boiler works at min. output, after decreasing of the required temperature is the fan switched on again and the boiler works at maximum output)
  6. Thermomanometer – shows the output temperature and the actual pressure of the heating water in boiler